Couplers and Wall Tie Bracket

1. Attach Coupler to Standard
Secure the scaffSAFE coupler to the upright standard using your licenced ScaffSafe key or ratchet. Do not use an impact driver or unlicenced tool.

2. Install Tube to Wall
Insert the 48mm tube to the wall, maintaining a 20mm gap from the facade. Tighten the coupler to the standard.

3. Fix Wall Tie Bracket
Attach the wall tie bracket to the tube, ensuring the base plate is flush with the facade, and properly secure it.

4. Drill & Install Anchor
Drill a hole using an approved drill bit, then blow and clean it. Install the anchor as per guidelines and re-tighten all connections.

5. Install Safety Coupler
Add a safety coupler if extra stability is required or requested.